S/N |
Test Item |
Standard(method) applied in full name & with serial No.( version of the year) |
Specified range |
||
---|---|---|---|---|---|
Item No. |
Descript. |
||||
1 | Surge protective devices — Low-voltage power distribution system |
1 | Full logo & Complete mark info |
Low-voltage surge protective devices— Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
|
2 | Logo /mark durable |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
|||
3 | Qualitative test for switch elements |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test 8/20µs short circuit impulse current at or below 160kA |
||
4 | 8/20µs impulse current test for measuring residual voltage |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test short-circuit impulse current at or below 160kA |
||
5 | 1.2/50µs impulse voltage test, measuring discharge voltage |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test open-circuit impulse voltage below 10kV |
||
6 | Pre-test to determine follow-current amount |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test prospective short-circuit with peak value up to 160kA |
||
7 | Pre-test of class I & II |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test 8/20µs short circuit impulse current at/ below 160kA |
||
8 | Class 1 & II Operation load test |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test① 8/20µs short circuit impulse current at/below 160kA ②10/350µs short circuit impulse current at /below 20kA |
||
9 | Load & endurable test of disconnector |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test① 8/20µs short circuit impulse current at or below 160kA ②10/350µs short circuit impulse current at /below 20kA |
||
10 | Thermal stability test |
GB18802.1-2011 Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
|||
11 | stand-by power consumption |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
|||
12 | Residue current |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
|||
13 | Surge endurable test on load side |
Low-voltage surge protective devices—Part 1:Performance requirements and testing methods -- GB18802.1-2011 |
Only test 8/20µs short circuit impulse current at or below 160kA |
||
2 | Surge protective devices connected to low-voltage distribution systems of telecommunication station/sites |
1 | Visual inspection |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
|
2 | Protection mode check |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
|||
3 | Warning function check |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
|||
4 | Limited voltage classification test |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
Only test short-circuit impulse current at or below 160kA |
||
5 | 8/20µs impulse Current to test residual voltage |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
Only test short-circuit impulse current at or below 160kA |
||
6 | 1.2/50µs impulse voltage to test discharge voltage |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
Only test the open circuit impulse voltage at or below 10kV |
||
7 | Pre-test of class I & II |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
Only test 8/20µs short-circuit impulse current at or below 160kA |
||
8 | Class 1 & II Operation load test |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
Only test① 8/20µs short circuit impulse current at or below 160kA ②10/350µs short circuit impulse current at /below 200kA |
||
10 | Class III Operation load test |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
Only test short-circuit impulse current of combination wave at 11kA or below and open circuit impulse voltage of 22kV or below. |
||
11 | Thermal Stability Test |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
|||
12 | Voltage drop test |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
|||
13 | Surge endurable test on load side |
Testing methods for surge protective devices connected to low-voltage distribution systems of telecommunication station/sites YD/T 1235.2-2002 |
|||
3 | Surge protective devices for signal networks |
1 | Visual inspection |
Technical Requirements and Testing Methods for Surge Protective Devices of Signaling Networks YD/T 1542-2006 |
|
2 | Max. continuous operation voltage test |
Technical Requirements and Testing Methods for Surge Protective Devices of Signaling Networks YD/T 1542-2006 |
|||
3 | Impulse current withstand test |
YD/T 1542-2006 Technical Requirements and Testing Methods for Surge Protective Devices of Signaling Networks YD/T 1542-2006 |
Only test short-circuit impulse current at or below 160kA
|
||
4 | Electric and electronic products |
1 | Low temperature test |
Environmental testing for electric and electronic products –Part 2: Test methods – Test A : Cold GB/T 2423.1-2008 |
|
2 | High temperature test |
Environmental testing for electric and electronic products –Part 2: Test methods – Test B :Dry heat GB/T 2423.2-2008 |
|||
3 | Heat and moisture test |
Environmental testing for electric and electronic products - Part 2: Testing method test Cab: Damp heat, Steady state GB/T 2423.3-2006 |
|||
4 | Alternating temperature humidity test |
Environmental testing for electric and electronic products –Part 2: Test methods – Test Db :Damp heat, cyclic (12h+12h cycle IDT) GB/T 2423.4-2008 |
|||
5 | Surge protective devices for railway signal system |
1 | Some test items |
Surge protective devices for Railway Signal System TB/T 2311-2008 |
|
6 | Surge protective device for photovoltaic application |
1 | Some test items |
Low voltage surge protective device- Surge protective device for specific application including D.C. Part 11: Requirements and Tests for SPDs in photovoltaic application FprEn50539-11:2012 |